Hand-Held EtCO2+SpO2 monitor AM-HC-30
Feature
- Slim shape, thickness is only 24mm,one-handed performance
- Easy operation with 4.0″ touch LCD display, screen lock function
- 16G mass storage, can store more than 100000 patient’s information and data
- Continuous real time when power off
- Patient’s information &data, tendency chart automatic storage when power off
- Auto brightness adjustment according to the environmental brightness changes
- Support 7-20 hours continuous work
Description
- Clinical significance
- Confirm the position and patency of trachea cannula
- Monitor the circulatory function / Evaluate the effectiveness of CPR
- Transport use
- Monitor the ventilation function
- Monitor the supersession function / Early diagnose malignant hyperthermia
- Find the fault of ventilator and Anaesthesia machine
- Auxiliary diagnosis of pulmonary embolism
- Good relativity with PaCO2 to reduce the frequency of blood gas analysis and palliate sufferings of patient.
III. Characteristic
- Read the data directly via PC, no need extra software
- Multifunctional USB port: storage, data output, fast charging
- Product Details
1.Patient data return visit
Review the patient’s information and measured data, tendency
2.Various mounting solution
Pole stand
Wall mounting rack
Desktop bracket
3.Remote network solution
WIFI, Bluetooth, APP, Telemedcine, Cloud service
4.Professional ETCO2 Solutions
Degermed, xerantic, integrated-sampling tube, fast plug in&out
AwRR 160/min
Support gas compensation (O2,N2O and other-anesthetic-gases
Built-in,side-stream,EtCO2 module, main-stream is optional
- Technical Specifications
- Size:148(L)*76(W)*24(H)
- Weight:250g
- Touch LCD display:4″ 800*600 dpi
- Internal memory:16G SD card
- Storage temperature:-20 °C – 55 °C
- Usage temperature:0 – 40 °C
- Humidity:15%-95%
- Power:5V DC,USB
- Charger:100-240V AC,50/60HZ
- Lithium battery:3.7V DC 3500mah
- Continuous working time:7 hour (CO2+SPO2)
- Out put:USB, BLE, WLAN, SPO2
- Range:0%-100%
- Precision:±2% ( 70%-100% Adult/Paed ),±3% ( 70%-100% Neonate )
- Resolution: ±1%
PR
Range:30-250BPM
Precision:±1BPM
SPO2
Range:0%-100%
Precision:
±2% (70%-100% Adult/Paed)
±3% (70%-100% Neonate)
Resolution:±1%
ETCO2
Range: 0-20% 0-150mmhg
Precision:
±2% 0-40mmhg
±5470mmhg
±8% 71-100mmhg
±10% 101-150mmhg
Sampling rate:50±10ml/min
AwRR
Range:3-160 rmp/min
Precision:±1rpm
Gas compensation:O2, N2O and anesthetic
Pressure compensation: automatic 400-800 mmhg
Sampling tube: degermed, xerantic, intergrated, fast plug in & out
Reviews
There are no reviews yet.