H2O2 Low Temperature Plasma Sterilizer AM-APS-1XP/2XP
Usage
ARI Plasma sterilizer takes H2O2 as sterilizing agent and form plasmatic state of H2O2 by electromagnetic field under low temperature. It combines both gaseous and plasmatic H2O2 to make sterilization for the items in chamber and decomposes the residual H2O2 after sterilization.
It is widely used in CSSD or other medical institute for the sterilization of electric wire and cable, optical glasses and glass lens, power equipment and batteries, endoscopes, catheter, nonmetallic and other wet or heat sensitive instruments.
Description
Technical Specifications
PARAMETER | SPECIFICATION | ||
Chamber dimension/volume | APS-1X/1XP:750D*450W*400Hmm/135L
APS-2X/2XP:1250D*450W*400Hmm/225L |
||
Chamber structure and material | Rectangular shape
Aluminum alloy material |
||
Overall dimension | APS-1X/1XP:990D×760Wx1600Hmm
APS-2X/2XP:1460D×760Wx1600Hmm |
||
Door quantity and type | Single door, floor standing,
automatic vertical sliding, operation on touch screen |
||
Loading method | Shelf loading, double layers | ||
Installation form | Installation on the ground | ||
Program | Standard cycle | flash cycle | Leak test |
Sterilization cycle time | ≤50mins | ≤26mins | |
Sterilization temperature | 50℃±5℃ | ||
Sterilization medium | H2O2 Solutions, 60% concentration | ||
H2O2 Solutions injection mode | Cassette type,
12 capsules on each cartridge 2.2ml H2O2 per capsule. |
||
H2O2 Solutions consumption | APS-1X/1XP: 2 capsules per full cycle, 1 capsules per flash cycle
APS-2X/2XP: 4 capsules per full cycle, 2 capsules per flash cycle |
||
Weight | 135L:400kg / 225L: 500Kg | ||
Power supply | Driving power: AC 380 V ± 10% 3 phases 50 Hz, 3.8kw(4.7kw) | ||
Display and operation | 5.7’’ true color Touch screen display and operation | ||
Data printer | Built-in thermal printer | ||
Loading method | Loading shelves | ||
Safety system | |||
Door safety | Adapts mandril-driving automatic door with reliable sealing function and safe lock device to guarantee the personal safety. | ||
Alarm | The machine equips with visible alarm information when error occurs. | ||
Environment safe | The matter after sterilization is water and oxygen molecule that have no toxic harm to staff or patient and there is no need for draining or air exhausting. | ||
Component material | |||
Packing size/G.W | 300mm*260mm*160mm, 3.5KG | ||
Component | Material | ||
Chamber | Aluminum alloy | ||
Chamber insulation material | High quality sponge | ||
Outside cover | Glass fiber reinforced plastics | ||
Door seal | Silicon rubber | ||
Chamber support | Carbon steel welded | ||
Pipeline system | Stainless steel and copper | ||
Internal loading rack | Stainless steel | ||
External transfer trolley | No. | ||
Configuration List | |||
Chamber body | PS100.1 | ARI | aluminum alloy chamber, both side welding, chamber warranty > 10 years |
Door | PS100.2 | ARI | Stainless steel and color glaze tempered glass |
PLC | CUP226 | SIEMENS, Germany | Strong function,advanced performance,high reliability, Multi communication mode. |
10’’ touch screen | T6457-D-S | ARI | Colorful display, real-time parameter display, convenient |
Printer | SPIB | ARI | Thermal printer, can print temperature, time, pressure and curve graph and sterilization result. |
Vacuum pump | ARI | High rate of flow, low noise | |
High precision pressure transmitter | Setra | USA | Import from America, High precision detection |
Pressure transmitter | Wika | Germany | Import from Germany, High accuracy |
Temperature sensor | PT-100 WIKA | Germany | |
Plasma power | ARI | High frequency | |
Solenoid valve | SMC, Japan | ||
Air filter | Sartorius stedim | ||
Biological Incubator
(APS-1XP, APS-2XP) |
The incubator is integrated with the equipment, and has independent control system, which can operate independently in the state of shutdown, and can be cultivated and operated conveniently. | ||
Curve for cycle | |||
Working process
Pre-vacuum → Pre-plasma → Ventilation 1 → Purification 1 →Diffusion1→ Ventilation2→ Vacuum2→ Plasma1 → Ventilation3 → Purification2 → Diffusion2 → Ventilation4 → Vacuum3 → Plasma2 → Ventilation5 |
|||
Standard and certificate | |||
ISO13485, CE. | |||
Consumables | |||
Name | Specification | Consumption | Photo reference |
H2O2 cassette | 12 capsules in one piece. | APS-1X/1XP:
2 standard cycles for each cassette APS-2X/2XP: 4 standard cycles for each cassette |
|
Biological indicator | 50 pieces in one box. | 2 pieces per day | |
Chemical indicator | 10cm x 1.8 cm
200 pieces in one bottle |
5-10 piece per cycle | |
Indicating Label for (Red/Green) | 2.5cm×6cm
18000pieces/20Bags/Case |
Depends on sterilizer items | |
Paper-plastic pouch | 75mm X 100m | Depends on sterilizer items | |
100mm X 100m | |||
150mm X 100m | |||
200mm X 100m | |||
250mm X100m | |||
300mm X100m | |||
Non-woven fabric cloth | 300mm×300m | Depends on sterilizer items | |
400mm×400m | |||
450mm×450m | |||
500mm×500m | |||
600mm×600m | |||
700mm×700m | |||
800mm×800m | |||
900mm×900m | |||
1000mm×1000m | |||
1100mm×1100m | |||
1200mm×1200m | |||
Sterilization Crepe Paper
(Color optional: Blue, White, Green) |
300mm×300m | Depends on sterilizer items | |
400mm×400m | |||
500mm×500m | |||
600mm×600m | |||
750mm×750m | |||
900mm×900m | |||
1000mm×1000m | |||
1200mm×1200m |