1500 Syringe Pump AM-ASP
Description
Features
- Open system: Accepts all standard syringes of 5ml, 10ml, 20ml/30ml, 50ml/60ml.
- Large COLOR LED display
- KVO/Bolus function.
- Vertical & Horizontal mounting.
- Anti-bolus system to reduce significantly after occlusion sudden release.
- Three levels of Occlusion Pressure Alarm.
- Three work modes: Rate Mode, Time Mode, Dose Mode
- Identify the specifications of syringe automatically.
- Audible and visual alarm: Syringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Key Holding During Infusion, Key Holding During Pause, Infusion Complete, Syringe Near Empty, No Action, Battery Low, Out of Flow Range
- Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions
- Power lost memory.
- Visual and audible alarm system and accurate injection rate make the process safer and reliable.
- Change the flow rate without stop during infusion.
- 8-10 Hours Internal Li-Battery continuous operation.
- Accurate and sensitive pressure sensor detects occlusion pressure accurately.
- Excellent injection operation. The accuracy will be ensured even at small-volume injection.
Technical Specifications
PARAMETER | SPECIFICATION |
Applicable syringes | 5ml,10ml,20ml,30ml,50ml,60ml of any standard |
Accuracy | +/- 2% with correct calibration |
Rate mode | 50ml(60ml): 0.1ml/h-2000.0ml/h (0.1ml/h or 1ml/h step)
30ml: 0.1ml/h-1200.0ml/h (0.1ml/h or 1ml/h step) 5ml: 0.1~200ml/h (0.1ml/h or 1ml/h step) |
Time Mode | SOL. VOL: 0.1-9999.9ml (0.1ml step) TIME: 00:01-99:59min (1min step) |
Dose Mode | Volume: 0.1-999.9ml (0.1ml step) DRUG MASS: 0.1-999.9mg 0.1mg step) DOSE: 0.001-9999ug/kg/min (0.001ug/kg/min step) WEIGHT: 0.1-300kg (0.1kg the least step)Dose unit: ng/kg/min, ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, U/h, IU/h, U/kg/h, ml/h |
Total Volume Range | 0.1-9999ml (0.1 ml step) |
Purge Rate | 50ml(60ml): 1500.0ml/h,
30ml: 1200.0ml/h, 20ml: 800.0ml/h 10ml: 400.0ml/h, 5ml: 200ml/h |
KVO Rate | 3ml/h when the delivery rate ≥3ml/h, otherwise KVO is the actual delivery rate |
DPS dynamic pressure | Three levels setting Low (60±15kPa), Medium (90±15kPa), High (120±15kPa) |
Alarms | Syringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Infusion Complete, Syringe Near Empty, No Action, Battery Low
Three levels of alarm volume LOW, MEDIUM or HIGH |
Bolus Rate | 5ml: 0.1~200ml/h,10ml:0.1-400ml/h,20ml:0.1-800ml/h,
30ml:0.1-1200ml/h,50ml(60ml):0.1-2000ml/h Programmable and adjustable |
Bolus Volume | Range: 1.0~50.0ml, (0.1ml step) |
Interface | RS-232 |
Power source | AC power supply: AC 100 to 240V( +/-10%),50/60Hz;
DC Power supply: 12~15V, power>15W; Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh. 8 -10hours of continuous operation |
Accessories: | AC power line, Operational manual |
Protection Class | Class I, Type CF, IP34 |
Dimension / N.W | 240mm*150mm*117mm, 2.0kg |
Packing size/G.W | 300mm*260mm*160mm, 3.0KG |